| General Info |
Model No. |
RS30KW/30.72KWH-ESS |
| Battery Data |
Battery type |
LiFePO4 |
|
Battery Cell capacity |
3.2V/100Ah |
|
Battery Cell combination |
51.2V 100AH, 6 units in series, 1 clusters |
|
Nominal capacity |
30.72kWh |
|
Rated voltage |
307.2V |
|
Voltage rage |
DC 268.8-340.8V |
|
Max charge/discharge current |
0.5C@25℃ |
|
DOD |
90% |
|
Cooling method |
Fan cooling |
| PV Input |
Max. input power |
39KW |
|
Max. input voltage |
1000V |
|
MPPT operating voltage range |
150-850V |
|
Start-up voltage |
180V |
|
Max. input current |
36+36+36A |
|
Max. short circuit current |
55+55+55A |
|
No. of MPPT trackers |
3 |
|
No. of strings per MPPT |
2+2+2 |
| AC Output |
Nominal output power |
30KW |
|
Normal output voltage |
230V/400V, 3L/N/PE |
|
Nominal output frequency |
50Hz/60Hz |
|
Max. output current |
43.5A |
|
Power factor |
0.8 leading to 0.8 lagging |
|
THDi |
<3% |
| Back-up Data |
Nominal output voltage |
230V/400V, 3L/N/PE |
|
Nominal output frequency |
50Hz/60Hz |
|
Normal output current |
43.5A |
|
Nominal output power |
30kW |
|
Switching time |
<20ms |
| System Data |
Dimensions (W×D×H) |
153012801740mm |
|
Weight |
1100kgs |
|
Protection grade |
IP54 |
|
Anti-corrosion grade |
C4 |
|
Operating temperature |
-20℃~55℃ |
|
Storage temperature |
-30℃~55℃ |
|
Relative humidity |
≤100% |
|
Temperature control |
Industrial air-conditioning |
|
Fire protection |
Aerosol |
|
Altitude |
≤3000m |
|
PCS cooling method |
Forced air cooling |
|
Communication protocol |
Modbus / RS485 |
|
Communication interface |
RJ45 |